DVM 32

(Download - PDF)

/// The 32 and 28 meter booms gain added versatility with the optional quick disconnect feature. Contractors use the truck-mounted pump with placing boom in its conventional mode for part of a day on slab pours or other ground level placements and quickly remove the boom (with the aid of a tower crane) for remote placements later in the day. The quick coupling incorporates four pins which are easily removed to free the boom from the truck. The boom is remounted to a Schwing pedestal using the four pin system. The pedestal can be located hundreds of feet from the pump and connected with a pipeline.



 

 

U.S.

Metric

Boom Design

ROLL and FOLD™

Horizontal Reach

138 ft

42 m

Reach Depth

75 ft

22.8 m

Coverage

59,835 sq. ft.

5,547 sq. m

Section Lengths

 

 

1st

66.25 ft

20.2 m

2nd

36.75 ft

11.2 m

3rd

28 ft

8.6 m

Rotation

720¾

Pipeline Diameter

5 in

125 mm

Control Systems

Radio - cable - manual

Boom weight

Available as split only

Split Boom option

 

 

-1A boom and Tower

9,000 lbs

4,082 kg

- 1B,2,3&4 Boom

10,200 lbs

4,626 kg

Specifications are subject to change without prior notice.